{"id":12251,"date":"2026-09-11T12:44:56","date_gmt":"2026-09-11T12:44:56","guid":{"rendered":"https:\/\/new-lights.com\/blog\/microwave-sensor-t8-led-tube-energy-savings\/"},"modified":"2026-09-12T19:40:58","modified_gmt":"2026-09-12T19:40:58","slug":"microwave-sensor-t8-led-tube-energy-savings","status":"publish","type":"post","link":"https:\/\/www.new-lights.com\/de\/blog\/microwave-sensor-t8-led-tube-energy-savings\/","title":{"rendered":"T8-R\u00f6hren mit Mikrowellensensor: So sch\u00fctzen Sie Energieeinsparungen"},"content":{"rendered":"<p>A microwave sensor does not make a T8 LED tube more efficient at producing light. It can reduce system energy by shortening full-output operation or moving the tube to a verified lower-power state when the controlled zone is unoccupied. The saving depends on the power of each state, how long the zone remains in that state, sensor behavior, time delay and the baseline used for comparison.<\/p>\n<p>The most defensible approach is to measure the existing system, define the proposed control sequence, commission the detection zone and calculate annual energy from state-by-state power and hours. A fixed percentage cannot replace those inputs.<\/p>\n<h2>Keep the Energy Mechanism Separate From LED Efficacy<\/h2>\n<p>Lumens per watt describes how much light a lamp or system produces for electrical input under stated conditions. Occupancy control changes when that system operates and at what power. It does not automatically change the efficacy of the LED package or driver.<\/p>\n<p>The Illuminating Engineering Society defines an occupancy sensor as a control device that detects presence, switches controlled equipment on and turns it off after a preset period without detected presence. A sensor-controlled T8 may instead use a high-to-low sequence rather than full on\/off, but the accounting principle is the same: energy changes only when operating time or input power changes.<\/p>\n<p>This page focuses on that occupancy-control calculation and commissioning task. The broader <a href=\"\/blog\/smart-t8-scheduling-automation-energy-savings\/\">smart T8 scheduling and automation guide<\/a> covers schedules, daylight response, networking and multiple control layers. Keeping the scopes separate prevents the same savings from being counted twice.<\/p>\n<h2>Define Every Operating State<\/h2>\n<p>Do not start with \u201coccupied\u201d and \u201cunoccupied\u201d as abstract labels. Record what the exact tube and control system do in each state.<\/p>\n<figure class=\"wp-block-table\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;\">\n<table>\n<thead>\n<tr>\n<th>Control state<\/th>\n<th>Required input<\/th>\n<th>What to verify<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Full output<\/td>\n<td>System input watts and delivered light<\/td>\n<td>Exact wiring, voltage, fixture and stabilized operating condition<\/td>\n<\/tr>\n<tr>\n<td>Delay period<\/td>\n<td>Power and duration after last detection<\/td>\n<td>Whether the lamp remains at full output or steps down first<\/td>\n<\/tr>\n<tr>\n<td>Low-output standby<\/td>\n<td>Input watts and maintained light level<\/td>\n<td>Measured power curve, minimum acceptable light and flicker behavior<\/td>\n<\/tr>\n<tr>\n<td>Off or sensor standby<\/td>\n<td>Residual lamp and sensor power<\/td>\n<td>Whether the sensor or driver continues to draw power<\/td>\n<\/tr>\n<tr>\n<td>Reactivation<\/td>\n<td>Response time and transition behavior<\/td>\n<td>Whether light returns safely without nuisance cycling<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>Use system input power at the electrical boundary being evaluated. A ballast-compatible tube includes ballast losses; a direct-wire tube has a different path. Sensor electronics and external control equipment also belong inside the boundary when they are dedicated to the project.<\/p>\n<p>For the published model options and electrical information, review the <a href=\"\/products\/led-tube-lights\/t8-led-tubes\/t8-microwave-motion-sensor-led-tube\/\">New Lights microwave-motion-sensor T8 tube page<\/a>. Do not transfer one model&#8217;s state power, delay or wiring to another model without the applicable data and instructions.<\/p>\n<h2>Understand What Microwave Detection Must Accomplish<\/h2>\n<p>Microwave sensing emits radio-frequency energy and evaluates motion-related changes in the reflected signal. This can support detection where a passive infrared sensor&#8217;s direct line of sight would be difficult, but the practical coverage still depends on sensor design, mounting, sensitivity, nearby materials and moving objects.<\/p>\n<p>Greater sensitivity is not automatically better. A detection zone that extends into an adjacent aisle, behind a lightweight partition or toward moving machinery can create false-on time. A zone that is too small or poorly oriented can miss slow or partially obstructed movement, causing an unwanted dim or off event.<\/p>\n<p>The UK Energy Technology List guidance describes microwave-based switching as useful in larger spaces, while federal lighting-control guidance emphasizes matching sensor type and location to the actual space. Neither statement is a model-level coverage promise. Commission the exact installation and record its boundaries.<\/p>\n<h2>Map Detection to a Real Control Timeline<\/h2>\n<p>The control sequence should describe what happens from first motion through vacancy and re-entry:<\/p>\n<ol>\n<li>Detection raises or switches the zone to the occupied state.<\/li>\n<li>Continued motion resets or maintains the occupancy timer.<\/li>\n<li>After the last valid detection, the preset delay runs.<\/li>\n<li>The system moves to low output or off, according to the approved sequence.<\/li>\n<li>New motion restores the occupied state within the required response time.<\/li>\n<\/ol>\n<figure class=\"wp-block-image nla-article-figure\" style=\"max-width:860px;margin-left:auto;margin-right:auto;\">\n<img loading=\"lazy\" class=\"wp-image-12767 skip-lazy\" data-no-lazy=\"1\" src=\"https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-sensor-t8-control-states-1.jpg\" width=\"1200\" height=\"800\" alt=\"Warehouse aisle sequence showing occupied, delay, low-output and reactivation lighting states\" loading=\"lazy\" decoding=\"async\" srcset=\"https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-sensor-t8-control-states-1.jpg 1200w, https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-sensor-t8-control-states-1-300x200.jpg 300w, https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-sensor-t8-control-states-1-1024x683.jpg 1024w, https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-sensor-t8-control-states-1-768x512.jpg 768w, https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-sensor-t8-control-states-1-18x12.jpg 18w, https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-sensor-t8-control-states-1-64x43.jpg 64w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption>Occupancy-responsive lighting saves energy only when the commissioned sequence replaces full-output time with a measured lower-power state.<\/figcaption><\/figure>\n<p>A long delay protects against nuisance dimming but reduces unoccupied savings. A short delay can save more energy in theory yet produce repeated transitions or unacceptable interruptions. Select the delay from observed use and safety requirements rather than from the lowest available setting.<\/p>\n<h2>Build the Baseline Before Calculating Savings<\/h2>\n<p>The baseline must describe what the lighting would consume without the proposed sensor control. Posted business hours are often insufficient. Include cleaning, restocking, shift overlap, maintenance, weekend access and existing manual switching.<\/p>\n<p>For a constant-power baseline:<\/p>\n<p><strong>Baseline kWh = quantity \u00d7 baseline system watts \u00d7 annual operating hours \u00f7 1,000<\/strong><\/p>\n<p>If the project replaces fluorescent lamps and adds sensors at the same time, separate equipment savings from control savings where measurements permit. First compare the existing system with an equivalent uncontrolled LED condition; then compare uncontrolled and sensor-controlled LED operation. This keeps the occupancy-control result from absorbing the entire retrofit benefit.<\/p>\n<p>The <a href=\"\/solutions\/fluorescent-lighting-replacement\/\">fluorescent lighting replacement solution<\/a> provides the wider retrofit context. The energy worksheet still needs measured system watts and real operating hours for the specific site.<\/p>\n<h2>Calculate the Controlled Load by State<\/h2>\n<figure style=\"max-width:900px;margin:32px auto;\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-12768\" src=\"https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-t8-energy-state-calculation.jpg\" alt=\"Energy calculation comparing baseline energy with full-output dimmed and standby operating states\" width=\"1400\" height=\"850\" srcset=\"https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-t8-energy-state-calculation.jpg 1400w, https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-t8-energy-state-calculation-300x182.jpg 300w, https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-t8-energy-state-calculation-1024x622.jpg 1024w, https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-t8-energy-state-calculation-768x466.jpg 768w, https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-t8-energy-state-calculation-18x12.jpg 18w, https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-t8-energy-state-calculation-64x39.jpg 64w\" sizes=\"(max-width: 1400px) 100vw, 1400px\" \/><figcaption>Estimate controlled energy from measured system power and observed time in each state, then compare it with the same site\u2019s baseline.<\/figcaption><\/figure>\n<p>For a simple high\/low\/off sequence:<\/p>\n<p><strong>Controlled kWh = quantity \u00d7 [(full watts \u00d7 full hours) + (low watts \u00d7 low hours) + (off-state watts \u00d7 off hours)] \u00f7 1,000 + dedicated control energy<\/strong><\/p>\n<p>The full, low and off hours must add up to the defined annual control window. If the sensor is active outside that window, include those hours too. Use measured power for the exact system; 50% light output does not necessarily mean 50% input power.<\/p>\n<p>Consider an illustrative 120-tube zone. The uncontrolled baseline is 18 W per tube for 4,000 hours, or 8,640 kWh per year. A commissioned sequence records 1,800 full-output hours, 2,000 low-output hours at 3 W and 200 off hours, plus 100 kWh of separate control energy. The controlled total is 4,708 kWh, a calculated reduction of 3,932 kWh for those assumptions.<\/p>\n<p>This worksheet is not a product or project forecast. Replace every input with measured or approved values. A different occupancy pattern, low-state power, delay or control boundary can change the result substantially.<\/p>\n<h2>Treat False-On and Missed Detection as Energy and Service Variables<\/h2>\n<p>False-on events add full-power time without serving the controlled zone. Missed detection can reduce measured energy while making the lighting unacceptable. Both belong in commissioning and post-installation review.<\/p>\n<figure class=\"wp-block-table\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;\">\n<table>\n<thead>\n<tr>\n<th>Observed behavior<\/th>\n<th>Likely question<\/th>\n<th>Commissioning action<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Lights activate from an adjacent aisle<\/td>\n<td>Is coverage extending beyond the intended zone?<\/td>\n<td>Reduce sensitivity, change orientation or revise zoning<\/td>\n<\/tr>\n<tr>\n<td>Lights stay high after traffic ends<\/td>\n<td>Is the delay too long or repeatedly reset?<\/td>\n<td>Log detections and compare them with actual movement<\/td>\n<\/tr>\n<tr>\n<td>Lights dim while people remain<\/td>\n<td>Is slow or obstructed motion being missed?<\/td>\n<td>Test representative tasks and sensor positions<\/td>\n<\/tr>\n<tr>\n<td>Frequent high-low cycling<\/td>\n<td>Is the delay too short or coverage unstable?<\/td>\n<td>Adjust delay and confirm transition behavior<\/td>\n<\/tr>\n<tr>\n<td>Entire aisle activates for one person<\/td>\n<td>Is the control zone larger than the task requires?<\/td>\n<td>Divide the zone where the architecture permits<\/td>\n<\/tr>\n<tr>\n<td>Light level is inadequate in standby<\/td>\n<td>Is the low state compatible with the required minimum?<\/td>\n<td>Measure illuminance and revise the low level or sequence<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>Commission with actual shelves, stock, doors, vehicles and operating equipment in place. An empty-building test can miss reflections or obstructions introduced during normal use.<\/p>\n<h2>Confirm the Electrical Architecture Before Installation<\/h2>\n<p>A sensor function does not answer how the tube is powered. Identify whether the model is ballast-compatible, ballast-bypass, single-ended, double-ended or uses another driver arrangement. Verify lampholders, internal shunts, supply conductors, fixture labels and market-specific instructions.<\/p>\n<p>The <a href=\"\/blog\/microwave-led-tube-single-ended-double-ended-power\/\">single-ended versus double-ended microwave-sensor T8 guide<\/a> covers this electrical decision. Electrical compatibility and energy-control behavior are separate acceptance items; passing one does not establish the other.<\/p>\n<p>Also check the tube&#8217;s behavior in every planned state. Measure input power, light output, flicker and power quality at full and low output where relevant. Confirm power restoration, repeated switching and interaction with other controls.<\/p>\n<h2>Protect Safety-Critical Lighting and Required Minimum Levels<\/h2>\n<p>Not every unoccupied signal permits complete darkness. Egress, emergency, security or process lighting may require a minimum state or a separate uncontrolled path. Federal occupancy-sensor guidance notes that some spaces are better served by dimming rather than switching off when immediate light is required.<\/p>\n<p>Define the emergency and failure behavior before calculating savings. What happens if the sensor fails, the driver loses control, power returns after an outage or the zone receives conflicting signals? Keep required operation inside the energy model rather than treating it as an afterthought.<\/p>\n<h2>Verify Savings After Commissioning<\/h2>\n<figure style=\"max-width:900px;margin:32px auto;\"><img decoding=\"async\" class=\"wp-image-12769\" src=\"https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-t8-commissioning-loop.jpg\" alt=\"Five-step microwave sensor commissioning loop from observation to recorded settings\" width=\"1400\" height=\"850\" srcset=\"https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-t8-commissioning-loop.jpg 1400w, https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-t8-commissioning-loop-300x182.jpg 300w, https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-t8-commissioning-loop-1024x622.jpg 1024w, https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-t8-commissioning-loop-768x466.jpg 768w, https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-t8-commissioning-loop-18x12.jpg 18w, https:\/\/www.new-lights.com\/wp-content\/uploads\/2026\/09\/microwave-t8-commissioning-loop-64x39.jpg 64w\" sizes=\"(max-width: 1400px) 100vw, 1400px\" \/><figcaption>Commissioning balances false-on operation, missed detection, energy use and required service before settings are recorded.<\/figcaption><\/figure>\n<p>The U.S. Department of Energy notes that configuration complexity can limit the performance of advanced lighting controls. Commissioning and later settings review therefore belong inside the savings plan rather than after it.<\/p>\n<p>The Lawrence Berkeley National Laboratory meta-analysis of commercial-building lighting controls reported a best estimate of 24% average savings for occupancy strategies across its filtered study set. That result describes a body of studies, not a microwave-sensor T8 guarantee. Site occupancy, baseline, space type, control settings and study method all affect the outcome.<\/p>\n<p>Plan measurement before installation. Use circuit meters, temporary loggers, control-state records or another suitable method with consistent boundaries. Compare representative periods and account for changes in shifts, production, weather, stocking or space use.<\/p>\n<p>Review the system again after handover. Sensitivity, delay, permanent overrides, blocked sensors and changed aisle layouts can erode savings or service quality. Record final settings and assign an owner for future changes.<\/p>\n<h2>Commissioning and Evidence Checklist<\/h2>\n<ul>\n<li>exact T8 model, wiring mode and fixture configuration;<\/li>\n<li>measured full, low and standby system power;<\/li>\n<li>light output and power quality in each used state;<\/li>\n<li>occupied, delay, low and off sequence;<\/li>\n<li>mounting height, orientation, sensitivity and intended zone;<\/li>\n<li>false-on and missed-detection observations during representative work;<\/li>\n<li>required minimum, emergency and failure states;<\/li>\n<li>measured baseline hours and system power;<\/li>\n<li>post-installation state hours or metered energy;<\/li>\n<li>final settings, responsible owner and change record.<\/li>\n<\/ul>\n<p>For a bounded product and energy review, <a href=\"\/contact\/\">contact New Lights<\/a> with the fixture architecture, operating schedule, occupancy pattern, state-power data, control settings and target market.<\/p>\n<h2>Frequently Asked Questions<\/h2>\n<h3 class=\"nls-toc-exclude\">Does a microwave sensor improve the tube&#8217;s lumens per watt?<\/h3>\n<p>No. It changes operating time or power state. Evaluate LED efficacy and occupancy-control energy separately.<\/p>\n<h3 class=\"nls-toc-exclude\">What percentage of energy will a sensor T8 save?<\/h3>\n<p>There is no universal percentage. Calculate the difference between measured baseline energy and the commissioned state-by-state load, including standby and dedicated controls.<\/p>\n<h3 class=\"nls-toc-exclude\">Is the shortest delay always best?<\/h3>\n<p>No. A shorter delay can reduce full-output time but may cause nuisance transitions or missed-service conditions. Use observed occupancy and task requirements.<\/p>\n<h3 class=\"nls-toc-exclude\">Can microwave sensing replace every PIR sensor?<\/h3>\n<p>No. Detection technology, coverage and false-trigger risk must match the space. Compare exact products under representative conditions.<\/p>\n<h3 class=\"nls-toc-exclude\">Does reduced runtime prove longer lamp life?<\/h3>\n<p>No. Fewer full-power hours may reduce some stresses, but rated life depends on the complete product, cycling, temperatures, components and the applicable evidence.<\/p>\n<h2 class=\"nls-toc-exclude\">Editorial Sources<\/h2>\n<ul>\n<li>Illuminating Engineering Society, <em>Occupancy Sensor<\/em>: https:\/\/ies.org\/definitions\/occupancy-sensor\/<\/li>\n<li>U.S. Department of Energy, <em>Lighting Controls Solutions<\/em>: https:\/\/www.energy.gov\/cmei\/ssl\/lighting-controls-solutions<\/li>\n<li>U.S. Federal Energy Management Program, <em>Wireless Occupancy Sensors for Lighting Controls<\/em>: https:\/\/www.energy.gov\/sites\/prod\/files\/2019\/12\/f70\/wireless_occupancy_sensor_guide.pdf<\/li>\n<li>Lawrence Berkeley National Laboratory, <em>A Meta-Analysis of Energy Savings from Lighting Controls in Commercial Buildings<\/em>: https:\/\/eta-publications.lbl.gov\/publications\/meta-analysis-energy-savings-lighting-controls-commercial-buildings<\/li>\n<li>UK Energy Technology List, <em>Lighting Technology Information Leaflet<\/em>: https:\/\/assets.publishing.service.gov.uk\/media\/65dc4bfa54f1e7f434165876\/Lighting_Technology_Information_Leaflet_April_2020.pdf<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Energieeinsparungen eines T8 mit Mikrowellensensor anhand gemessener Leistungszust\u00e4nde, Belegung, Zeitverz\u00f6gerung, Steuerungsverhalten und Verifizierung nach der Installation sch\u00fctzen.<\/p>","protected":false},"author":1,"featured_media":12770,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_angie_page":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"page_builder":"","footnotes":""},"categories":[150],"tags":[],"class_list":["post-12251","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-led-technology"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.new-lights.com\/de\/wp-json\/wp\/v2\/posts\/12251","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.new-lights.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.new-lights.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.new-lights.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.new-lights.com\/de\/wp-json\/wp\/v2\/comments?post=12251"}],"version-history":[{"count":2,"href":"https:\/\/www.new-lights.com\/de\/wp-json\/wp\/v2\/posts\/12251\/revisions"}],"predecessor-version":[{"id":12772,"href":"https:\/\/www.new-lights.com\/de\/wp-json\/wp\/v2\/posts\/12251\/revisions\/12772"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.new-lights.com\/de\/wp-json\/wp\/v2\/media\/12770"}],"wp:attachment":[{"href":"https:\/\/www.new-lights.com\/de\/wp-json\/wp\/v2\/media?parent=12251"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.new-lights.com\/de\/wp-json\/wp\/v2\/categories?post=12251"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.new-lights.com\/de\/wp-json\/wp\/v2\/tags?post=12251"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}