Panel LED de emisión lateral para Norteamérica
- Five Regional Footprints: Square, half-width and full-length formats address common North American ceiling-module proportions.
- Side-Emission Optical Body: La distribución luminosa de emisión lateral permite una construcción de panel delgada, distinta de los productos retroiluminados.
- Model-Specific Output: Each footprint uses its specified wattage options for accurate project selection.
- White Ceiling Finish: A consistent white frame keeps all five proportions visually aligned in ceiling layouts.
| Panel formats | 303 x 303 to 603 x 1213 mm |
|---|---|
| Potencia nominal | 12-72 W by footprint |
| Eficacia luminosa | 110-150 lm/W; personalizable |
| Temperatura de color | 3000-5000 K |
|---|---|
| Tensión de entrada | 100-277 V |
| Ángulo de haz | 112 grados |
Technical Specifications
Model Specifications
| Modelo | Dimensions | Rated Power | Efficacy | CCT Range | CRI Options | Voltage | PF |
|---|---|---|---|---|---|---|---|
| XGYPL-SE-3030-E12 | 303 x 303 mm | 12 W | 110-150 lm/W | 3000-5000 K | Ra80/90 | 100-277 V | 0.9 |
| XGYPL-SE-3060-E24 | 303 x 603 mm | 24 W | 110-150 lm/W | 3000-5000 K | Ra80/90 | 100-277 V | 0.9 |
| XGYPL-SE-6060-E40 | 603 x 603 mm | 40 W | 110-150 lm/W | 3000-5000 K | Ra80/90 | 100-277 V | 0.9 |
| XGYPL-SE-6060-E40 | 603 x 603 mm | 48 W | 110-150 lm/W | 3000-5000 K | Ra80/90 | 100-277 V | 0.9 |
| XGYPL-SE-6060-E40 | 603 x 603 mm | 60 W | 110-150 lm/W | 3000-5000 K | Ra80/90 | 100-277 V | 0.9 |
| XGYPL-SE-30120-E40 | 303 x 1213 mm | 40 W | 110-150 lm/W | 3000-5000 K | Ra80/90 | 100-277 V | 0.9 |
| XGYPL-SE-30120-E40 | 303 x 1213 mm | 48 W | 110-150 lm/W | 3000-5000 K | Ra80/90 | 100-277 V | 0.9 |
| XGYPL-SE-30120-E40 | 303 x 1213 mm | 60 W | 110-150 lm/W | 3000-5000 K | Ra80/90 | 100-277 V | 0.9 |
| XGYPL-SE-60120-E60 | 603 x 1213 mm | 60 W | 110-150 lm/W | 3000-5000 K | Ra80/90 | 100-277 V | 0.9 |
| XGYPL-SE-60120-E60 | 603 x 1213 mm | 72 W | 110-150 lm/W | 3000-5000 K | Ra80/90 | 100-277 V | 0.9 |
No Flicker; dimmable option; 50000 h; indoor use; white finish; 112-degree beam; PF 0.9. Luminous efficacy is customizable.
Product Description
Product Details
Product Construction
A perimeter-mounted optical system works with a separate rear driver housing. The family is specified with No Flicker, a dimmable option, Ra80/90 options, 50000 h lifetime and indoor use.
Selection & Installation Notes
Measure the actual ceiling grid and choose the exact 303, 603 or 1213 mm size before ordering. Confirm the selected rating, CCT, driver and dimming configuration before approval. Multiple power values in one row are order options unless a field-selectable driver is specifically approved. For metric and oversized ceiling formats, compare our large-format LED panels.
Recommended Application
Applications
- North American Offices: Match the selected footprint to the measured recessed ceiling grid.
- Meeting Rooms: Coordine la potencia seleccionada y la temperatura de color con el plan de iluminación de la estancia.
- Education Interiors: Utilice el formato cuadrado o lineal compatible en techos interiores de aulas y zonas administrativas.
- Retail Fit-Outs: Seleccione la proporción del panel según el módulo y la disposición del techo del inquilino.
en contacto
- N.º 5, Fenghuang Road, Zona Industrial de Qianjiang, localidad de Dingqiao, Haining, Zhejiang 314413, China
- +86-18358315743
- R.KOO@NEW-LIGHTS.COM
Frequently Asked Questions?
Encuentre respuestas claras a las preguntas habituales sobre especificaciones de producto, selección de modelos, aplicaciones y requisitos de presupuesto. Para necesidades específicas de un proyecto, envíenos su mercado de destino, la cantidad requerida y las especificaciones clave.
No. Mida la retícula real antes de sustituir, porque las dimensiones exteriores son diferentes.
XGYPL-SE-30120-E40 corresponde al formato de 303 x 1213 mm. Verifique la separación real de los perfiles en T y el método de soporte.
Not automatically. Rows with multiple wattages describe order options unless a selectable driver is specifically approved and labeled.
La familia está disponible de 3000 K a 5000 K. Confirme el CCT solicitado antes del muestreo.
La regulación figura como opción. Confirme el driver exacto y la interfaz de control para el modelo solicitado.
These panels are intended for compatible indoor recessed ceiling applications. No outdoor or IP-rated configuration is specified.