U-Shaped UV-C Germicidal Lamps
- U-Shaped Lamp Geometry: The folded profile provides a return path within the lamp body.
- Replaceable Equipment Component: The lamp format supports service replacement in compatible UV-C equipment.
- UV-C Germicidal Source: The lamp is intended as a UV-C source for purpose-designed germicidal equipment.
| Lamp form | U-shaped clear Φ16 mm return tube |
|---|---|
| Rated power | 18–55 W |
| Base / connection | Single-ended 2-pin base |
| Primary wavelength | 253.7 nm UV-C |
| Ozone choice | Non-ozone or ozone-generating variant; 185 nm applies to the ozone option |
|---|---|
| Supply boundary | Lamp only; holder, ballast, enclosure and safeguards are separate |
| Rated lifetime / warranty | 8,000–10,000 h / 1 year |
Technical Specifications
Model Specifications
| Model | Dimensions | Connection | Rated Power | Spectrum | Listed UV-C Intensity (μW/cm²) |
|---|---|---|---|---|---|
| XGYG18T5LU-UVC-E18 | Φ16 × 201 mm | 2-pin | 18 W | UVC | 56 |
| XGYG24T5LU-UVC-E24 | Φ16 × 287 mm | 2-pin | 24 W | UVC | 80 |
| XGYG30T5LU-UVC-E30 | Φ16 × 353 mm | 2-pin | 30 W | UVC | 93 |
| XGYG36T5LU-UVC-E40 | Φ16 × 429 mm | 2-pin | 40 W | UVC | 108 |
| XGYG48T5LU-UVC-E55 | Φ16 × 582 mm | 2-pin | 55 W | UVC | 157 |
Listed UV-C intensity values are provided for the lamp components. Measurement distance, geometry and test conditions are not provided, so the values are not for cross-model performance comparison or finished-system design.
Product Description
Product Details
Product Construction
Parallel glass sections join at the closed end to create the visible profile. Handle and support the selected reference according to its approved equipment documentation.
Selection & Installation Notes
Before release, verify dimensional fit, connector arrangement, circuit requirements and any specified configuration. Provide suitable shielding, access controls, labels and servicing procedures because direct UV-C exposure can injure eyes and skin. See our UV-C germicidal category for related formats.
Recommended Application
Applications
- Air Treatment Equipment: Integrate the selected lamp into enclosed UV-C equipment designed to treat moving air.
- Water Treatment Equipment: Use the matched reference in shielded reactor assemblies designed for UV-C water treatment.
- Surface Treatment Cabinets: Install the lamp within enclosed cabinets that control access during a treatment cycle.
- OEM Germicidal Systems: Build the approved lamp reference into purpose-designed UV-C equipment with matched mechanical and electrical interfaces.
in touch
- No.5 Fenghuang Road Qianjiang Industrial Area Dingqiao Town Haining Zhejiang 314413 China
- +86-18358315743
- R.KOO@NEW-LIGHTS.COM
Frequently Asked Questions?
Find clear answers to common questions about product specifications, model selection, applications, and quotation requirements. For project-specific needs, send us your target market, required quantity, and key specifications.
It is used in purpose-designed UV-C air-treatment, water-treatment, surface-treatment and OEM germicidal equipment.
Match the complete reference, dimensions, connection arrangement and operating circuit to the approved equipment documentation.
No. UV-C exposure can injure eyes and skin, so the lamp belongs in equipment with suitable containment and access controls.
The equipment must provide the specified mechanical support, electrical system, containment, controls, labeling and service safeguards.
Use a different shape only after the equipment manufacturer verifies mechanical fit, electrical compatibility and the required UV-C configuration.
Follow the equipment lockout and service instructions, prevent UV-C exposure and use the complete approved replacement reference.