New Lights

Tri-Proof Fixture (SMD – GS | OS Series)

Tri-Proof Fixture (SMD – GS | OS Series) is a linear luminaire family organized around separate GS and OS order references. Select the approved configuration from the project requirements, drawing and complete specification.
  • Linear Luminaire Form: The product family uses an elongated fixture format for coordinated lighting runs.
  • GS And OS Series: Separate series identities support configuration-level product selection.
  • SMD Fixture Identity: The page covers an SMD luminaire family while component relationships remain tied to the approved order reference.
Selection BasisComplete order reference and production sample
Drawing ReviewAvailable envelope and fixing plan
Installation ReviewSupporting surface, cable entry and service access
Electrical ReviewRequired supply, driver and control method
Optical ReviewProject output, distribution and color requirements
Environment ReviewSite exposure and required enclosure protection

Technical Specifications

Model Specifications

ModelSeriesDimensions L×W×H (mm)ClipsRated PowerEfficacyCCT
XGYLEDTPSGS-E18GS600×85.5×78618 W95 lm/W3000–6500 K
XGYLEDTPSGS-E20GS600×85.5×78620 W95 lm/W3000–6500 K
XGYLEDTPSGS-E36GS1200×85.5×78836 W95 lm/W3000–6500 K
XGYLEDTPSGS-E40GS1200×85.5×78840 W95 lm/W3000–6500 K
XGYLEDTPSGS-E54GS1500×85.5×781054 W95 lm/W3000–6500 K
XGYLEDTPSGS-E60GS1500×85.5×781060 W95 lm/W3000–6500 K
XGYLEDTPSOS-E18OS600×105×78618 W95 lm/W3000–6500 K
XGYLEDTPSOS-E20OS600×105×78620 W95 lm/W3000–6500 K
XGYLEDTPSOS-E36OS1200×105×781036 W95 lm/W3000–6500 K
XGYLEDTPSOS-E40OS1200×105×781040 W95 lm/W3000–6500 K
XGYLEDTPSOS-E54OS1500×105×781454 W95 lm/W3000–6500 K
XGYLEDTPSOS-E60OS1500×105×781460 W95 lm/W3000–6500 K

Product Description

Product Details

Product Construction

Each ordered unit follows its signed specification; this page does not assign one material stack, cover, clip or sealing arrangement, or one light-source and driver relationship across the GS and OS series. Component inclusion and replacement access require configuration-level documentation.

Selection & Installation Notes

Verify the available envelope, supporting surface, fixing plan, cable entry and service clearance. Record the required supply, control method, optical targets and environmental exposure in the project specification before sample approval. Compare related formats in our tri-proof and waterproof fixture range.

Recommended Application

Applications

  • Workshop Lighting Runs: Plan linear luminaires across work areas and circulation routes with approved site provisions.
  • Warehouse Aisles: Coordinate fixture positions above storage and handling routes in the lighting layout.
  • Utility Corridors: Use the selected configuration along service passages with defined installation conditions.
  • Covered Loading Areas: Place linear fixtures beneath covered handling zones where the approved configuration matches the site exposure.
Keep
in touch

Tell Us Your Market and Product Needs

Share your market, product interest, application, or estimated quantity. Our team can help you move faster from product selection to quotation and sample discussion.

Frequently Asked Questions?

Find clear answers to common questions about product specifications, model selection, applications, and quotation requirements. For project-specific needs, send us your target market, required quantity, and key specifications.

What is the difference between the GS and OS series?

They are separate order-reference groups within this product family. The series names do not establish one shared width, material, electrical package or protection configuration.

What does SMD identify on this fixture page?

SMD is part of the assigned product identity. It does not by itself establish the light-source layout, driver relationship, replacement method or complete electrical package for every configuration.

Does the tri-proof name establish one IP rating?

No. Confirm the required enclosure protection, sealing arrangement and site conditions for the selected order configuration.

Are the light source and driver included in every configuration?

The family name does not establish a universal inclusion boundary. Verify the light-source, driver, wiring and replacement arrangement in the approved specification.

How should the correct GS or OS reference be selected?

Match the complete order reference to the approved drawing, installation envelope, electrical requirements, optical targets and environmental conditions.

What can New Lights configure for an OEM/ODM project?

We can configure the approved housing, cover, electrical arrangement, labeling and packaging around the confirmed order reference and production sample.

Featured Products

Scroll to Top

Send Us a Message

Leave your contact details and message. Our team will reply by email or through your preferred contact method.

Tell Us About Your Lighting Project

Share your product, application and purchasing requirements. Our lighting team will reply with suitable options and project support.