New Lights

Tubos LED T5/T6 con controlador interno

Estos tubos LED T5 y T6 G5 integran el controlador dentro de cuerpos de lámpara de 16 o 19 mm para iluminación lineal de AC directa, con seis longitudes, potencias discretas de 5-22 W y opciones de tensión única o universal. Son adecuados para luminarias interiores correctamente cableadas utilizadas para iluminación de trabajo en oficinas, comercios, educación y hostelería.
  • Flicker-Free Operation: The no-flicker IC circuit supports comfortable general lighting in occupied indoor spaces.
  • Multiple Optical Finishes: Clear, frosted and shatter-retention choices cover different diffusion and handling requirements by tube type.
  • Dimmable Versions Available: Los modelos regulables proporcionan una salida ajustable para proyectos que requieren control de iluminación.
  • Rated Service Life: A 25,000-hour rated lifetime supports routine indoor replacement cycles.
Tube FormatsT5: Dia. 16 mm / T6: Dia. 19 mm
Length Range288 / 549 / 849 / 1000 / 1149 / 1449 mm
Rated Power5 / 9 / 12 / 16 / 18 / 22 W
Entrada y PFS: AC 180-265 V, PF >0.5 / U: AC 85-265 V, PF >0.9
Método de entradaEstándar de alimentación por un extremo / alimentación por ambos extremos configurable
Eficacia y CCT80-150 lm/W; 3000-8000 K
CRI y hazCRI 70 / 80 / 90 / 95 / 97; 320 grados

Technical Specifications

Model Specifications

Model No.TubeTamaño diám. x L (mm)Rated / EqV.Input / PFEfficacyCCTCRI
XGYT5B301ID-E5T516 x 2885 W / 8 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT6B301ID-E5T619 x 2885 W / 8 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT5B302ID-E9T516 x 5499 W / 14 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT6B302ID-E9T619 x 5499 W / 14 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT5B303ID-E12T516 x 84912 W / 21 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT6B303ID-E12T619 x 84912 W / 21 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT5B304aID-E16T516 x 100016 W / 26 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT6B304aID-E16T619 x 100016 W / 26 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT5B304ID-E18T516 x 114918 W / 28 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT6B304ID-E18T619 x 114918 W / 28 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT5B305ID-E22T516 x 144922 W / 35 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT6B305ID-E22T619 x 144922 W / 35 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97

S indica el controlador de tensión única indicado y U el controlador de tensión universal. El método de entrada, el acabado del tubo y la construcción de los casquillos deben coincidir con la configuración y el diagrama de instalación confirmados.

Product Description

Product Details

Product Construction

These G5 bi-pin linear lamps place the LED board and power electronics inside a straight glass-based tube body. The paired series uses separate 16 mm T5 and 19 mm T6 mechanical platforms, with PC or aluminum end-cap construction selected for the confirmed configuration.

Selection & Installation Notes

Select the exact T5 or T6 model by diameter, length and discrete power, then match the single-voltage or universal-voltage driver and the ordered single- or double-ended input method. Direct-AC installation requires the fixture wiring to follow the supplied diagram, with the fluorescent ballast removed or bypassed as specified before the tube is energized.

Recommended Application

Applications

  • Office Task Lighting: Provide linear illumination above desks, work counters and circulation areas in correctly wired G5 fixtures.
  • Retail Shelving: Illuminate merchandise shelves, display cases and checkout work areas with compact T5 or T6 tube lengths.
  • Classrooms and Libraries: Ilumine mesas de lectura, espacios de enseñanza y pasillos entre estanterías de libros con iluminación lineal sin parpadeo.
  • Hotel Service Areas: Light corridors, utility counters and back-of-house workspaces fitted with direct-AC linear fixtures.
Mantente
en contacto

Indíquenos su mercado y sus necesidades de producto

Indíquenos su mercado, el producto de interés, la aplicación o la cantidad estimada. Nuestro equipo puede ayudarle a avanzar más rápido desde la selección del producto hasta la oferta y el análisis de muestras.

Frequently Asked Questions?

Encuentre respuestas claras a las preguntas habituales sobre especificaciones de producto, selección de modelos, aplicaciones y requisitos de presupuesto. Para necesidades específicas de un proyecto, envíenos su mercado de destino, la cantidad requerida y las especificaciones clave.

¿Cuál es la diferencia entre las versiones T5 y T6?

Los modelos T5 utilizan un diámetro de 16 mm y una construcción mate. Los modelos T6 utilizan un diámetro de 19 mm y admiten opciones transparentes, mates o de retención de fragmentos dentro de la configuración confirmada.

Does this internal-driver tube operate through the old fluorescent ballast?

No para la configuración de AC directa. El balasto fluorescente debe retirarse o puentearse, y la luminaria debe cablearse según el diagrama suministrado para el tubo pedido.

¿Puede el tubo utilizar alimentación por un extremo o por ambos extremos?

Sí. La serie admite una configuración estándar de entrada por un extremo y una versión configurable de entrada por ambos extremos; la etiqueta de la lámpara y el cableado de la luminaria deben utilizar el mismo método.

¿Cuál es la diferencia entre las opciones de controlador S y U?

S identifica la versión indicada de AC 180-265 V con PF superior a 0.5, mientras que U identifica la versión de tensión universal AC 85-265 V con PF superior a 0.9.

¿Qué opciones ópticas están disponibles para esta serie?

Las opciones disponibles abarcan 80-150 lm/W, 3000-8000 K, CRI 70, 80, 90, 95 o 97, y un formato de haz de 320 grados. Confirme la combinación seleccionada para cada configuración de pedido.

¿Qué certificaciones están disponibles para estos tubos T5/T6?

El conjunto de certificaciones disponible incluye CE, CB, INMETRO, RoHS y ErP, con conformidad respaldada por TUV disponible para configuraciones confirmadas. Las marcas suministradas deben coincidir con la configuración de producción confirmada.

Featured Products

Scroll al inicio

Send Us a Message

Deje sus datos de contacto y su mensaje. Nuestro equipo responderá por correo electrónico o a través del medio de contacto que prefiera.

Háblenos de su proyecto de iluminación

Indique sus requisitos de producto, aplicación y compra. Nuestro equipo de iluminación responderá con opciones adecuadas y apoyo para el proyecto.