Lampade fluorescenti UV-A/BLB a luce nera
- Fluorescence Visibility: The optical output reveals compatible fluorescent markings while limiting distracting visible lamp glow.
- Fixture Geometry Choice: Linear and folded shapes support both long housings and space-conscious equipment layouts.
- Separate Lamp Replacement: La sorgente luminosa può essere sottoposta a manutenzione senza sostituire un idoneo involucro dell'apparecchio.
- Defined Illumination Role: La lampada fornisce luce di eccitazione, mentre lo strumento completo e l'operatore determinano il risultato dell'ispezione.
| Tipo di lampada | Lampada fluorescente a luce nera UV-A/BLB |
|---|---|
| Peak Wavelength | 365 nm |
| Glass | Vetro nero |
| Formati disponibili | T5, T8, T10, T12, PL-S e PL-L |
|---|---|
| Installazione | Abbinare la forma e l'attacco della lampada al portalampada |
| Operating Gear | Richiesto alimentatore esterno compatibile per lampade fluorescenti |
Technical Specifications
Model Specifications
| Modello | Lamp Form | Tube Diameter (mm) | Lunghezza totale (mm) | Attacco / Base | Rated Power |
|---|---|---|---|---|---|
| XGYT5-BLB-4W | T5 | 16 | 135.9 | G5 | 4 W |
| XGYT5-BLB-6W | T5 | 16 | 212.1 | G5 | 6 W |
| XGYT5-BLB-8W | T5 | 16 | 288.3 | G5 | 8 W |
| XGYT5-HO-BLB-15W | T5 HO | 16 | 288.3 | G5 | 15 W |
| XGYT5-BLB-14W | T5 | 16 | 549 | G5 | 14 W |
| XGYT5-BLB-21W | T5 | 16 | 849 | G5 | 21 W |
| XGYT5-BLB-28W | T5 | 16 | 1149 | G5 | Confermare con la scheda di progetto |
| XGYT8-BLB-10W | T8 | 26 | 331 | G13 | 10 W |
| XGYT8-BLB-15W | T8 | 26 | 437.4 | G13 | 15 W |
| XGYT8-BLB-18W | T8 | 26 | 589.8 | G13 | 18 W |
| XGYT8-BLB-30W | T8 | 26 | 894.6 | G13 | 30 W |
| XGYT8-BLB-36W | T8 | 26 | 1199.4 | G13 | 36 W |
| XGYT8-BLB-58W | T8 | 26 | 1500 | G13 | 58 W |
| XGYT10-BLB-20W | T10 | 32 | 589.8 | G13 | 20 W |
| XGYT10-BLB-40W | T10 | 32 | 1199.4 | G13 | 40 W |
| XGYT12-BLB-20W | T12 | 38 | 589.8 | G13 | 20 W |
| XGYT12-BLB-40W | T12 | 38 | 1199.4 | G13 | 40 W |
| XGYPLS-5W-BLB | PL-S | 12 | 85 | G23 / 2G7 | 5 W |
| XGYPLS-7W-BLB | PL-S | 12 | 115 | G23 / 2G7 | 7 W |
| XGYPLS-9W-BLB | PL-S | 12 | 145 | G23 / 2G7 | 9 W |
| XGYPLS-11W-BLB | PL-S | 12 | 215 | G23 / 2G7 | 11 W |
| XGYPLS-13W-BLB | PL-S | 12 | 155 | GX23 / 2G7 | 13 W |
| XGYPLL-18W-BLB | PL-L | 18 | 225 | 2G11 | 18 W |
| XGYPLL-24W-BLB | PL-L | 18 | 320 | 2G11 | 24 W |
| XGYPLL-55W-BLB | PL-L | 18 | 535 | 2G11 | 55 W |
| XGYPLL-36W-BLB | PL-L | 18 | 415 | 2G11 | 36 W |
Product Description
Product Details
Product Construction
La lampada combina un sistema al fosforo UV-A con un bulbo in vetro nero che assorbe la maggior parte dell'emissione visibile. Le versioni lineari T5, T8, T10 e T12 utilizzano terminali bi-pin, mentre le versioni PL-S e PL-L ripiegano il tubo di scarica in un formato compatto a innesto.
Selection & Installation Notes
Select the lamp by physical form, tube diameter, overall length and holder interface, then confirm the rated electrical specification and compatible external control gear for the final order reference. Plug-in base options require project confirmation because different holder interfaces are not interchangeable. Compare adjacent products in our UV-A and blacklight lamp range.
Recommended Application
Applicazioni
- Document Fluorescence Viewers: Provides UV-A/BLB illumination in compatible equipment used to reveal fluorescent document features.
- Laboratory Fluorescence Viewing: Supports enclosed laboratory viewing equipment designed around a 365 nm blacklight source.
- Process Inspection Equipment: Excites fluorescent markers in compatible indoor inspection systems and viewing stations.
- Indoor Blacklight Fixtures: Serve programmi di sostituzione e di apparecchi OEM che utilizzano lampade fluorescenti a luce nera diritte o compatte.
in contatto
- No.5 Fenghuang Road Qianjiang Industrial Area Dingqiao Town Haining Zhejiang 314413 China
- +86-18358315743
- R.KOO@NEW-LIGHTS.COM
Descrivici le esigenze del tuo mercato e dei tuoi prodotti
Condividi il tuo mercato, l’interesse per il prodotto, l’applicazione o la quantità stimata. Il nostro team può aiutarti ad accelerare il passaggio dalla selezione del prodotto alla quotazione e alla discussione sui campioni.
Frequently Asked Questions?
Trova risposte chiare alle domande comuni su specifiche del prodotto, selezione del modello, applicazioni e requisiti per il preventivo. Per esigenze specifiche di progetto, inviaci il mercato di destinazione, la quantità richiesta e le specifiche principali.
Match the physical lamp form, tube diameter, overall length and holder interface first. Then confirm the rated electrical specification and external control gear for the final order reference.
Questa famiglia è una sorgente a luce nera UV-A da 365 nm con bulbo in vetro nero. Non è una lampada germicida UV-C e non deve essere selezionata per la disinfezione.
No. Fornisce illuminazione UV-A/BLB in grado di rivelare caratteristiche fluorescenti. L'autenticazione dipende dal sistema di osservazione completo, dalle caratteristiche di riferimento e dalla procedura utilizzata dall'operatore.
Sì. Utilizzare l'alimentatore compatibile per lampade fluorescenti e il portalampada specificato per la configurazione della lampada selezionata.
No. Confermare per l'ordine l'esatto attacco a innesto e l'interfaccia del portalampada, poiché le diverse configurazioni di attacco non sono intercambiabili.
L'esatta pagina ufficiale del prodotto elenca CE e RoHS. Confermare il file del certificato applicabile per il modello ordinato e il mercato di destinazione.