| Type de lampe | Lampe fluorescente lumière noire UV-A/BLB |
|---|---|
| Peak Wavelength | 365 nm |
| Glass | Verre noir |
| Formes disponibles | T5, T8, T10, T12, PL-S et PL-L |
|---|---|
| Installation | Adaptez la forme et le culot de la lampe à la douille |
| Operating Gear | Appareillage de commande fluorescent externe compatible requis |
Technical Specifications
Model Specifications
| Modèle | Lamp Form | Tube Diameter (mm) | Longueur totale (mm) | Culot / douille | Rated Power |
|---|---|---|---|---|---|
| XGYT5-BLB-4W | T5 | 16 | 135.9 | G5 | 4 W |
| XGYT5-BLB-6W | T5 | 16 | 212.1 | G5 | 6 W |
| XGYT5-BLB-8W | T5 | 16 | 288.3 | G5 | 8 W |
| XGYT5-HO-BLB-15W | T5 HO | 16 | 288.3 | G5 | 15 W |
| XGYT5-BLB-14W | T5 | 16 | 549 | G5 | 14 W |
| XGYT5-BLB-21W | T5 | 16 | 849 | G5 | 21 W |
| XGYT5-BLB-28W | T5 | 16 | 1149 | G5 | À confirmer avec la fiche projet |
| XGYT8-BLB-10W | T8 | 26 | 331 | G13 | 10 W |
| XGYT8-BLB-15W | T8 | 26 | 437.4 | G13 | 15 W |
| XGYT8-BLB-18W | T8 | 26 | 589.8 | G13 | 18 W |
| XGYT8-BLB-30W | T8 | 26 | 894.6 | G13 | 30 W |
| XGYT8-BLB-36W | T8 | 26 | 1199.4 | G13 | 36 W |
| XGYT8-BLB-58W | T8 | 26 | 1500 | G13 | 58 W |
| XGYT10-BLB-20W | T10 | 32 | 589.8 | G13 | 20 W |
| XGYT10-BLB-40W | T10 | 32 | 1199.4 | G13 | 40 W |
| XGYT12-BLB-20W | T12 | 38 | 589.8 | G13 | 20 W |
| XGYT12-BLB-40W | T12 | 38 | 1199.4 | G13 | 40 W |
| XGYPLS-5W-BLB | PL-S | 12 | 85 | G23 / 2G7 | 5 W |
| XGYPLS-7W-BLB | PL-S | 12 | 115 | G23 / 2G7 | 7 W |
| XGYPLS-9W-BLB | PL-S | 12 | 145 | G23 / 2G7 | 9 W |
| XGYPLS-11W-BLB | PL-S | 12 | 215 | G23 / 2G7 | 11 W |
| XGYPLS-13W-BLB | PL-S | 12 | 155 | GX23 / 2G7 | 13 W |
| XGYPLL-18W-BLB | PL-L | 18 | 225 | 2G11 | 18 W |
| XGYPLL-24W-BLB | PL-L | 18 | 320 | 2G11 | 24 W |
| XGYPLL-55W-BLB | PL-L | 18 | 535 | 2G11 | 55 W |
| XGYPLL-36W-BLB | PL-L | 18 | 415 | 2G11 | 36 W |
Product Description
Product Details
Product Construction
La lampe associe un système de phosphore UV-A à une ampoule en verre noir qui absorbe la majeure partie de l’émission visible. Les versions droites T5, T8, T10 et T12 utilisent des culots bipin, tandis que les versions PL-S et PL-L replient le tube à décharge dans un format compact enfichable.
Selection & Installation Notes
Select the lamp by physical form, tube diameter, overall length and holder interface, then confirm the rated electrical specification and compatible external control gear for the final order reference. Plug-in base options require project confirmation because different holder interfaces are not interchangeable. Compare adjacent products in our UV-A and blacklight lamp range.
Recommended Application
Applications
- Document Fluorescence Viewers: Provides UV-A/BLB illumination in compatible equipment used to reveal fluorescent document features.
- Laboratory Fluorescence Viewing: Supports enclosed laboratory viewing equipment designed around a 365 nm blacklight source.
- Process Inspection Equipment: Excites fluorescent markers in compatible indoor inspection systems and viewing stations.
- Indoor Blacklight Fixtures: Convient aux programmes de remplacement et d'appareils OEM utilisant des lampes fluorescentes droites ou compactes à lumière noire.
en contact
- No.5 Fenghuang Road Qianjiang Industrial Area Dingqiao Town Haining Zhejiang 314413 China
- +86-18358315743
- R.KOO@NEW-LIGHTS.COM
Indiquez-nous votre marché et vos besoins en produits
Indiquez votre marché, les produits qui vous intéressent, l’application ou la quantité estimée. Notre équipe peut vous aider à accélérer le passage de la sélection des produits au devis et à l’échange sur les échantillons.
Frequently Asked Questions?
Trouvez des réponses claires aux questions fréquentes sur les spécifications produit, le choix des modèles, les applications et les exigences de devis. Pour des besoins propres à un projet, envoyez-nous votre marché cible, la quantité requise et les principales spécifications.
Match the physical lamp form, tube diameter, overall length and holder interface first. Then confirm the rated electrical specification and external control gear for the final order reference.
Cette famille est une source de lumière noire UV-A de 365 nm avec une ampoule en verre noir. Il ne s’agit pas d’une lampe germicide UV-C et elle ne doit pas être choisie pour la désinfection.
Non. Elle fournit un éclairage UV-A/BLB pouvant révéler des éléments fluorescents. L’authentification dépend du système d’observation complet, des éléments de référence et de la procédure utilisée par l’opérateur.
Oui. Utilisez un appareillage de commande fluorescent compatible et la douille spécifiée pour la configuration de lampe sélectionnée.
Non. Confirmez le culot enfichable exact et l’interface de douille pour la commande, car les différentes configurations de culot ne sont pas interchangeables.
La page produit officielle exacte indique CE et RoHS. Confirmez le fichier de certificat applicable au modèle commandé et au marché de destination.