Tubo LED T8 con sensore di movimento a microonde
- Activity-Based Energy Saving: Sleeping behavior reduces unnecessary full-output operation in intermittently occupied areas by up to 95%.
- Controlled Fade-Back Timing: The waiting period prevents an immediate return to the reduced state after a brief pause in movement.
- Background Wayfinding: The lower-output state preserves orientation light between full-brightness events.
- Compact Automatic Lamp: Sensing and illumination share one replaceable tubular form instead of separate lamp and detector products.
| Sensor & Response | High-frequency microwave motion sensor; instant start |
|---|---|
| Montaggio e rilevamento | 3-4.5 m recommended height; 5-8 m radius; approx. 120 degrees |
| Tempo di mantenimento | 45 s standard; configurabile fino a 3 min |
| Standby Output | 3 W standard; configurable 1-10 W |
|---|---|
| Size & Rated Power | Dia. 26 x L 590 / 1199 / 1499 mm; 9 / 18 / 22 W; G13 |
| Light & Electrical | 80-160 lm/W; 3000-8000 K; Ra70/80; no flicker; 25,000 h; AC 180-265 V or AC 85-265 V; PF 0.5/0.9; indoor |
Technical Specifications
Model Specifications
| Model No. | Dimensioni Dia. x L (mm) | Potenza | Sostituzione | Efficacy | CCT |
|---|---|---|---|---|---|
| XGYT8B102MS-E9 | 26 x 590 | 9 W | 18 W | 80-160 lm/W | 3000-8000 K |
| XGYT8B104MS-E18 | 26 x 1199 | 18 W | 36 W | 80-160 lm/W | 3000-8000 K |
| XGYT8B105MS-E22 | 26 x 1499 | 22 W | 58 W | 80-160 lm/W | 3000-8000 K |
Recommended sensor installation: 3-4.5 m height, 5-8 m radius and approximately 120-degree coverage. Standard hold time is 45 seconds, configurable up to 3 minutes; standby output is 3 W standard and configurable from 1 W to 10 W.
Product Description
Product Details
Product Construction
The 26 mm G13 tube combines an opal diffuser, LED board, driver and a microwave sensor module positioned at the marked end collar. The sensor responds through the lamp body without requiring a separate detector on the ceiling.
Selection & Installation Notes
Scegliere il modello da 590, 1199 o 1499 mm e abbinare la relativa potenza nominale di 9, 18 o 22 W all'apparecchio. Posizionare la lampada entro l'altezza di montaggio consigliata di 3-4.5 m, quindi impostare il tempo di mantenimento e l'uscita in standby in base al flusso di passaggio; strutture metalliche, pareti e movimenti esterni all'area prevista possono modificare la zona di rilevamento effettiva.
Recommended Application
Applicazioni
- Parking Garages: Raise light output as vehicles or pedestrians move through protected indoor parking aisles.
- Warehouse Aisles: Provide full light during activity and a lower standby level between visits to storage zones.
- Service Corridors: Respond to intermittent foot traffic in indoor back-of-house and utility circulation areas.
- Indoor Stairwells: Trigger light as people enter enclosed stair and landing areas with compatible linear fixtures.
in contatto
- No.5 Fenghuang Road Qianjiang Industrial Area Dingqiao Town Haining Zhejiang 314413 China
- +86-18358315743
- R.KOO@NEW-LIGHTS.COM
Descrivici le esigenze del tuo mercato e dei tuoi prodotti
Condividi il tuo mercato, l’interesse per il prodotto, l’applicazione o la quantità stimata. Il nostro team può aiutarti ad accelerare il passaggio dalla selezione del prodotto alla quotazione e alla discussione sui campioni.
Frequently Asked Questions?
Trova risposte chiare alle domande comuni su specifiche del prodotto, selezione del modello, applicazioni e requisiti per il preventivo. Per esigenze specifiche di progetto, inviaci il mercato di destinazione, la quantità richiesta e le specifiche principali.
The built-in high-frequency microwave module detects movement and triggers instant full-light operation within the configured sensing and timing settings.
Il catalogo consiglia un'altezza di montaggio di 3-4.5 m, con un raggio di rilevamento di 5-8 m e una copertura di circa 120 gradi.
Sì. Il tempo di mantenimento standard è di 45 secondi e può essere configurato fino a 3 minuti.
Sì. Il livello standard di standby è 3 W e l'intervallo configurabile supportato è 1-10 W.
Yes. Metalwork, room boundaries and movement outside the target zone can change the practical sensing pattern, so the installed lamp must be checked in its intended position.
No. Questa serie è destinata all'uso interno e non ha una classificazione dichiarata per esterni o ambienti umidi.