Opbouwsets met T8-buizen en armaturen
- Local Switching Option: Selected variants place a switch beside the lampholder for local operation.
- Link-Through Connection: Dedicated end hardware supports continuous-row connection on compatible variants.
- Series-Specific Steel Gauges: Chassis families use 0.20, 0.25 or 0.30 mm steel according to the selected series.
- Relampable Assembly: De lichtbron blijft afzonderlijk vervangbaar nadat het chassis is gemonteerd.
| Lamp / voet | Vervangbare T8-buis / G13 |
|---|---|
| Inhoud van de set | T8-buis + bedraad armatuur van gelakt staal in krimpverpakking |
| Montage / lengtes | Surface mounted / 600, 900, 1200 or 1500 mm |
| Buisopstellingen | Enkele of dubbele buis / behuizing zonder reflector of met reflector |
|---|---|
| Elektrische uitvoeringen | Direct AC / magnetic ballast / electronic ballast |
| Directe AC-ingang | Enkelzijdig of dubbelzijdig, afgestemd op de meegeleverde buis |
Technical Specifications
Model Specifications
V8-buisarmatuur — magnetisch voorschakelapparaat
| Model No. | Dimensions | Tube / Lamp Power | Staaldikte |
|---|---|---|---|
| XGY-T8-V820 | 600 × 50 × 63 (28) mm | 1 × 18 W | 0.25 mm |
| XGY-T8-V830 | 900 × 50 × 63 (28) mm | 1 × 30 W | 0.25 mm |
| XGY-T8-V840 | 1200 × 50 × 63 (28) mm | 1 × 36 W | 0.25 mm |
| XGY-T8-DV820 | 600 × 83 × 63 (28) mm | 2 × 18 W | 0.25 mm |
| XGY-T8-DV830 | 900 × 83 × 63 (28) mm | 2 × 30 W | 0.25 mm |
| XGY-T8-DV840 | 1200 × 83 × 63 (28) mm | 2 × 36 W | 0.25 mm |
V8-buisarmatuur + reflector — magnetisch voorschakelapparaat
| Model No. | Dimensions | Tube / Lamp Power | Staaldikte |
|---|---|---|---|
| XGY-T8-SZM6 | 600 × 125 (50) × 66 (31) mm | 1 × 18 W | 0.25 mm |
| XGY-T8-SZM9 | 900 × 125 (50) × 66 (31) mm | 1 × 30 W | 0.25 mm |
| XGY-T8-SZM12 | 1200 × 125 (50) × 66 (31) mm | 1 × 36 W | 0.25 mm |
| XGY-T8-DZM6 | 600 × 163 (83) × 66 (31) mm | 2 × 18 W | 0.25 mm |
| XGY-T8-DZM9 | 900 × 163 (83) × 66 (31) mm | 2 × 30 W | 0.25 mm |
| XGY-T8-DZM12 | 1200 × 163 (83) × 66 (31) mm | 2 × 36 W | 0.25 mm |
V3-buisarmatuur — elektronisch voorschakelapparaat
| Model No. | Dimensions | Tube / Lamp Power | Staaldikte |
|---|---|---|---|
| XGY-T8-V320 | 600 × 40 × 59 (24) mm | 1 × 18 W | 0.30 mm |
| XGY-T8-V330 | 900 × 40 × 59 (24) mm | 1 × 30 W | 0.30 mm |
| XGY-T8-V340 | 1200 × 40 × 59 (24) mm | 1 × 36 W | 0.30 mm |
| XGY-T8-V320A | 600 × 40 × 59 (24) mm | 1 × 18 W | 0.25 mm |
| XGY-T8-V330A | 900 × 40 × 59 (24) mm | 1 × 30 W | 0.25 mm |
| XGY-T8-V340A | 1200 × 40 × 59 (24) mm | 1 × 36 W | 0.25 mm |
| XGY-T8-V320FA | 600 × 74 (40) × 59 (24) mm | 2 × 18 W | 0.25 mm |
| XGY-T8-V330FA | 900 × 74 (40) × 59 (24) mm | 2 × 30 W | 0.25 mm |
| XGY-T8-V340FA | 1200 × 74 (40) × 59 (24) mm | 2 × 36 W | 0.25 mm |
V3-buisarmatuur + reflector — elektronisch voorschakelapparaat
| Model No. | Dimensions | Tube / Lamp Power | Staaldikte |
|---|---|---|---|
| XGY-T8-V320AR | 600 × 125 (40) × 59 (24) mm | 1 × 18 W | 0.25 mm |
| XGY-T8-V330AR | 900 × 125 (40) × 59 (24) mm | 1 × 30 W | 0.25 mm |
| XGY-T8-V340AR | 1200 × 125 (40) × 59 (24) mm | 1 × 36 W | 0.25 mm |
| XGY-T8-V320FAR | 600 × 125 (40) × 59 (24) mm | 2 × 18 W | 0.25 mm |
| XGY-T8-V330FAR | 900 × 125 (40) × 59 (24) mm | 2 × 30 W | 0.25 mm |
| XGY-T8-V340FAR | 1200 × 125 (40) × 59 (24) mm | 2 × 36 W | 0.25 mm |
Inter-connectable Single Tube Fixture — Direct AC
| Model No. | Dimensions | Tube / Lamp Power | Staaldikte |
|---|---|---|---|
| XGY-T8-SPM6A | 600 × 33 × 49 (14) mm | 1 × 18 W | 0.20 mm |
| XGY-T8-SPM9A | 900 × 33 × 49 (14) mm | 1 × 30 W | 0.20 mm |
| XGY-T8-SPM12A | 1200 × 33 × 49 (14) mm | 1 × 36 W | 0.20 mm |
Single / Double Tube Fixture — Direct AC
| Model No. | Dimensions | Tube / Lamp Power | Staaldikte |
|---|---|---|---|
| XGY-T8-SPM6 | 600 × 33 × 49 (14) mm | 1 × 18 W | 0.20 mm |
| XGY-T8-SPM9 | 900 × 33 × 49 (14) mm | 1 × 30 W | 0.20 mm |
| XGY-T8-SPM12 | 1200 × 33 × 49 (14) mm | 1 × 36 W | 0.20 mm |
| XGY-T8-SPM15 | 1500 × 33 × 49 (14) mm | 1 × 58 W | 0.20 mm |
| XGY-T8-SPM6F | 600 × 74 (33) × 49 (14) mm | 2 × 18 W | 0.20 mm |
| XGY-T8-SPM9F | 900 × 74 (33) × 49 (14) mm | 2 × 30 W | 0.20 mm |
| XGY-T8-SPM12F | 1200 × 74 (33) × 49 (14) mm | 2 × 36 W | 0.20 mm |
Cap-Folding Single Tube Fixture — Direct AC
| Model No. | Dimensions | Tube / Lamp Power | Staaldikte |
|---|---|---|---|
| XGY-T8-DPM6A | 600 × 34 × 51 (16) mm | 1 × 18 W | 0.20 mm |
| XGY-T8-DPM9A | 900 × 34 × 51 (16) mm | 1 × 30 W | 0.20 mm |
| XGY-T8-DPM12A | 1200 × 34 × 51 (16) mm | 1 × 36 W | 0.20 mm |
| XGY-T8-DPM6B | 600 × 34 × 51 (16) mm | 1 × 18 W | 0.30 mm |
| XGY-T8-DPM9B | 900 × 34 × 51 (16) mm | 1 × 30 W | 0.30 mm |
| XGY-T8-DPM12B | 1200 × 34 × 51 (16) mm | 1 × 36 W | 0.30 mm |
Broad-Base Double Tube Fixture — Direct AC
| Model No. | Dimensions | Tube / Lamp Power | Staaldikte |
|---|---|---|---|
| XGY-T8-OP6 | 600 × 83 × 66 (31) mm | 2 × 18 W | 0.30 mm |
| XGY-T8-OP9 | 900 × 83 × 66 (31) mm | 2 × 30 W | 0.30 mm |
| XGY-T8-OP12 | 1200 × 83 × 66 (31) mm | 2 × 36 W | 0.30 mm |
| XGY-T8-OP6Z | 600 × 163 (31) × 66 (31) mm | 2 × 18 W | 0.30 mm |
| XGY-T8-OP9Z | 900 × 163 (31) × 66 (31) mm | 2 × 30 W | 0.30 mm |
| XGY-T8-OP12Z | 1200 × 163 (31) × 66 (31) mm | 2 × 36 W | 0.30 mm |
Waarden van geprofileerde beugels blijven onderdeel van de afmetingen van elk model. Selecteer eerst de armatuurstructuur en het elektrische formaat en combineer deze vervolgens met de bijpassende G13 T8 lamp en het bedradingsschema.
Product Description
Product Details
Product Construction
Each set combines a G13 T8 tube with a painted-steel surface-mounted fixture. Depending on the model family, the body uses a narrow single-lamp channel, a wider two-lamp channel, a formed reflector, a folding-end-cap profile or a broad base. The matched tube and wired fixture are enclosed together in protective shrink packaging.
Selection & Installation Notes
Identify whether the building circuit uses direct AC, a magnetic ballast or an electronic ballast, then choose the corresponding fixture family. Next match the required length, lamp count, body width and reflector format. For direct-AC versions, match the tube input method to the lampholder wiring. Use these sets on dry indoor surfaces. Browse other linear batten options.
Recommended Application
Toepassingen
- Garages and Utility Rooms: Provide replaceable-lamp general lighting across dry indoor parking bays, workbenches and storage zones.
- Workshops and Warehouses: Arrange single- or double-tube fixtures in repeated surface-mounted rows above production and storage aisles.
- Retail Backrooms: Install shrink-packed tube-and-fixture sets in stockrooms, service corridors and other dry support spaces.
- Indoor Retrofit Projects: Match direct-AC or ballast-based fixture structures to the selected T8 lamp and existing electrical plan.
in contact
- No.5 Fenghuang Road Qianjiang Industrial Area Dingqiao Town Haining Zhejiang 314413 China
- +86-18358315743
- R.KOO@NEW-LIGHTS.COM
Frequently Asked Questions?
Vind duidelijke antwoorden op veelgestelde vragen over productspecificaties, modelselectie, toepassingen en offertevereisten. Stuur ons voor projectspecifieke behoeften uw doelmarkt, vereiste hoeveelheid en belangrijkste specificaties.
Ja. Elke set combineert een T8 buis met een bedraad, gelakt stalen armatuur in beschermende krimpverpakking. Specificeer bij bestelling het vereiste lampvermogen, CCT, de buisconstructie en de elektrische invoermethode.
Stem de armatuurfamilie af op de gekozen lamp en het gebouwcircuit. V8-modellen gebruiken formaten met magnetisch voorschakelapparaat, V3-modellen gebruiken formaten met elektronisch voorschakelapparaat, en SPM-, DPM-, OP- en doorverbindbare modellen gebruiken directe AC.
Ja, beide ingangsconfiguraties zijn beschikbaar. De bestelde buis, lamphouders en interne bedrading moeten dezelfde configuratie gebruiken; volg daarom het bedradingsschema van de geselecteerde set.
Single-tube models use a narrow one-lamp body, double-tube models provide two lamp positions, and reflector versions use a wider formed body around the lampholders. Select by lamp count and available mounting width.
These sets are intended for dry indoor surfaces. Use a separately rated waterproof or tri-proof product for damp, wet or wash-down locations.
Ja. Schakel het circuit spanningsloos, controleer of de vervangende buis overeenkomt met het armatuurcircuit en de ingangsconfiguratie, en installeer deze vervolgens volgens het toepasselijke bedradingsschema.