New Lights

Tubes LED T5/T6 à alimentation externe

External-driver T5 and T6 LED tubes use 16 mm or 19 mm glass-and-PET bodies with G5 caps for fluorescent-fixture conversion. Six lengths cover 5-22 W with single- or double-ended input configurations.
  • External Driver Architecture: Locating the driver outside the tube separates the electronic control from the slim lamp body.
  • Paired T5 and T6 Range: Each listed length is available in both a 16 mm T5 body and a 19 mm T6 body.
  • Wide Tubular Distribution: A 320-degree beam supports broad linear illumination from compatible fixtures.
  • High-CRI Options: CRI selections extend from 70 to 97 for different color-rendering requirements.
  • Defined Service Rating: The series lists a 25,000-hour rated lifetime with a two-year warranty.
Tube FormatsT5 Dia. 16 mm / T6 Dia. 19 mm
Length & Rated PowerL 288-1449 mm / 5-22 W
Replacement Range8-35 W fluorescent equivalent
Entrée / facteur de puissanceS: AC 180-265 V / PF >0.5; U: AC 85-265 V / PF >0.9
Light Options80-150 lm/W ; 3000-8000 K ; CRI 70 / 80 / 90 / 95 / 97
Construction & ConnectionGlass + PET; G5 PC or aluminum caps; single- or double-ended input

Technical Specifications

Model Specifications

Model No.TubeDimensions D x L (mm)Rated / EqV.Input / PFEfficacyCCTCRI
XGYT5B301ED-E5T516 x 2885 W / 8 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT6B301ED-E5T619 x 2885 W / 8 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT5B302ED-E9T516 x 5499 W / 14 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT6B302ED-E9T619 x 5499 W / 14 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT5B303ED-E12T516 x 84912 W / 21 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT6B303ED-E12T619 x 84912 W / 21 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT5B304aED-E16T516 x 100016 W / 26 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT6B304aED-E16T619 x 100016 W / 26 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT5B304ED-E18T516 x 114918 W / 28 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT6B304ED-E18T619 x 114918 W / 28 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT5B305ED-E22T516 x 144922 W / 35 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT6B305ED-E22T619 x 144922 W / 35 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97

All listed models use a glass-and-PET body, G5 caps and single- or double-ended input. PC and aluminum cap constructions, clear or frosted diffusion finishes and dimmable versions are available by confirmed configuration. The series uses SMD2835 LEDs with a 320-degree beam and lists a 25,000-hour rated lifetime with a two-year warranty.

Product Description

Product Details

Product Construction

The lamp combines SMD2835 LEDs with a glass-and-PET tube body, G5 bi-pin caps and a separate external IC driver. Clear or frosted diffusion finishes and fire-resistant PC or aluminum cap constructions provide the visible build options.

Selection & Installation Notes

Select the exact model by diameter, length, rated power, S or U input version, power factor, cap construction, diffusion finish and single- or double-ended connection. For fluorescent-fixture conversion, remove the existing ballast and install the specified external-driver system according to its supplied wiring diagram. Dimmable versions are available only when configured for the order.

Recommended Application

Applications

  • Offices and Homes: Provide slim linear general lighting in offices, corridors and residential utility spaces.
  • Retail Stores: Illuminate supermarket aisles, shelving zones and shopping areas with continuous linear light.
  • Hotels and Restaurants: Use compact linear fixtures for back-of-house, corridor and service-area lighting.
  • Schools and Healthcare: Provide general indoor illumination in classrooms, circulation areas and non-procedure support spaces.
  • Parking and Garages: Install the matched tube-and-driver system in protected indoor parking and garage fixtures.
Restons
en contact

Indiquez-nous votre marché et vos besoins en produits

Indiquez votre marché, les produits qui vous intéressent, l’application ou la quantité estimée. Notre équipe peut vous aider à accélérer le passage de la sélection des produits au devis et à l’échange sur les échantillons.

Frequently Asked Questions?

Find clear answers to common questions about product specifications, model selection, applications, and quotation requirements. For project-specific needs, send us your target market, required quantity, and key specifications.

What is the difference between the T5 and T6 versions?

The T5 tube is 16 mm in diameter and the T6 tube is 19 mm. Both formats are listed in the same six lengths and power levels.

Le ballast fluorescent reste-t-il dans le circuit ?

No. For a fluorescent-fixture conversion, remove the existing ballast and install the specified external driver according to the supplied wiring diagram.

Can these tubes use single-ended or double-ended input?

Yes. Both arrangements are listed, but the installed wiring must match the ordered tube-and-driver configuration.

Quelles options de corps et de capuchon d'extrémité sont disponibles ?

La série comprend des constructions en verre et PET transparent ou dépoli, avec des capuchons d'extrémité G5 en PC résistant au feu ou en aluminium.

Quelles spécifications lumineuses peuvent être sélectionnées ?

The listed options cover 80-150 lm/W, 3000-8000 K and CRI 70, 80, 90, 95 or 97.

Are dimmable versions available?

Yes. Dimmable models are available as a configured option and must be confirmed with the matching external driver before production.

Featured Products

Retour en haut

Send Us a Message

Leave your contact details and message. Our team will reply by email or through your preferred contact method.

Tell Us About Your Lighting Project

Share your product, application and purchasing requirements. Our lighting team will reply with suitable options and project support.