A tripod LED work light moves illumination close to a temporary task without installing a permanent luminaire. The same portability also creates design constraints: elevated heads can cause glare, hard shadows and wind load, while folding legs and power cables introduce impact and trip hazards.

Choose the complete setup, not the highest wattage. Define the work area and viewing task, model delivered light, aim both heads, verify the stand on the actual surface, plan the electrical route and test the production-intent unit under representative conditions.

Diagram showing two tripod work-light heads aimed to create complementary coverage
Twee verstelbare koppen kunnen aangrenzende taakzones bestrijken, maar het goedgekeurde resultaat hangt af van gemeten plaatsing en uitrichting.
SelectievraagAan te vragen bewijsVoorkomen storing
Hoeveel bruikbaar licht bereikt de taak?Totale lichtstroom, IES/LDT-bestand en meting op locatieHotspots met donkere werkzones
Kan het statief stabiel blijven staan?Hoogte, grondvlak, massa en stabiliteitsinstructiesOmvallen door wind, impact of trekkracht op de kabel
Is het elektrische pakket geschikt?Spanning, stekker, snoer, bescherming en marktdocumentenSchok, oververhitting en beschadigde kabels
Kan het de omgeving verdragen?IP- en temperatuurbewijs op modelniveauOnjuist gebruik in regen, stof of ongeschikte locaties
Kunnen teams het herhaaldelijk hanteren?Ingeklapte afmetingen, opstelprocedure en inspectieplanStoringen bij beknelling, transport en onderhoud

Begin met de huidige productconfiguratie

De huidige New Lights Dual-Head LED Flood Light Tripod uses two independently adjustable flood heads on a raised crossbar and folding tripod. The product page positions the two-head arrangement for adjacent temporary task areas and instructs buyers to confirm head power, coverage, glare, input voltage, total load, cable route, plug exposure and stand stability.

That current identity is more reliable than carrying historical model rows into a new article. The retrieved current page does not publish a complete model-level photometric or mechanical table, so approval should remain tied to the exact offered head, driver, stand, cable and plug package.

New Lights dual-head LED flood light on a folding yellow tripod
Het huidige product met dubbele kop combineert verstelbare schijnwerperkoppen, een dwarsbalk, telescopische mast, inklapbare poten en een voedingsaansluiting met snoer.

Vergelijk voor andere formaten op grondniveau en met draagframe de portable IP65 LED flood light. De keuze van de uitvoering moet volgen uit plaatsing, hantering en kabelbehoeften, niet alleen uit het uiterlijk van het product.

Bepaal het werkgebied voordat u de output selecteert

Measure the area that needs light and mark where people work, walk, drive and handle materials. Record task-plane height, obstructions, reflective surfaces, machinery and glare-sensitive viewing directions. Separate general circulation from detailed assembly, inspection, repair or camera work.

Applicable workplace rules may set minimum illumination levels, but a minimum does not prove uniformity or visual comfort. Define maintained illuminance, minimum-to-average ratio where relevant, acceptable glare and the background level around the task. The RFQ-checklist voor magazijnverlichting biedt een breder kader voor het documenteren van geometrie, bedrijfstoestanden en acceptatiecriteria.

The work boundary also determines how many tripods are needed. One bright stand may be easy to deploy yet create deep shadows behind workers or equipment. Two lower-output positions can sometimes deliver better visibility with less direct glare.

Vergelijk geleverd licht, niet alleen het vermogen

Wattage describes electrical input, not how light reaches a surface. Request total lumens and an IES or LDT file for the exact head and optical configuration. Model both heads at the intended height, tilt and spacing, then check the result on the real task grid.

Photometric inputVastleggenOndersteunde beslissing
WerkvlakHoogte, afmetingen en oriëntatieMeetgrid en doelniveau
MontageStatiefpositie, masthoogte en kanteling van de kopBundelplaatsing en schaduwrichting
LichtverdelingExact IES/LDT-bestandGemiddelde, minimale en maximale verlichtingssterkte
OmgevingReflectantie, obstakels en achtergrondRisico op verblinding en adaptatie
BedrijfstoestandBeide koppen, één kop en voedingsconditieElke beoogde gebruiksmodus

De algemene LED floodlight selection guide explains the relationship among output, optics, working distance and coverage. A wide beam label by itself cannot predict site illuminance because distance, tilt and room geometry change the footprint.

Richt twee koppen om schaduwen en verblinding te beheersen

Use the two heads deliberately. Aim one toward the primary task and the other toward an adjacent or shadowed area rather than overlapping both beams at the same point. Adjust one head at a time while monitoring the task grid.

Place the tripod outside primary sight lines and vehicle paths. Aim down toward the task instead of across the horizon. Observe the layout with workers, tools and machinery in their normal positions; an empty floor can conceal obstruction shadows.

New Lights dual-head tripod work light illuminating a temporary work area
Een representatief beeld van de locatie helpt problemen met verblinding, schaduw, toegang en kabelrouting zichtbaar te maken die een productafbeelding op een witte achtergrond niet kan tonen.

If one head creates a bright hot spot, do not assume that raising output is the solution. Reposition the stand, spread the beams, add background illumination or use another light direction. The goal is usable visibility across the task, not the highest meter reading at one point.

Controleer hoogte, vergrendelingen en mechanische staat

Raise the mast only as high as needed to clear obstructions and distribute light. Greater height increases the moment applied at the base and can make wind, impact or cable pull more consequential. Lock every telescopic section and head-adjustment joint according to the product instructions.

Inspect play, damaged threads, worn clamps, missing feet and deformed members. Confirm that the crossbar and heads do not rotate or drop after repeated adjustment. A replaceable or adjustable component is useful only when the connector, fasteners and service procedure are controlled.

Do not carry an energized tripod or lift it by the cable. Define whether one person can safely deploy the complete kit, and use two-person handling where the actual mass or site procedure requires it.

Beoordeel stabiliteit op het werkelijke oppervlak

Concrete, compacted soil, gravel, slope and soft ground produce different support conditions. Open the legs fully, place every foot on stable contact and maintain a protected footprint around the stand. Keep the mast within the documented operating height.

Diagram showing head height, wind, ground contact and cable pull as tripod stability factors
De stabiliteit van een statief wordt bepaald door de volledige situatie op locatie, niet alleen door de vorm van de poten.
StabiliteitsfactorControle op locatieVereiste beheersmaatregel
MasthoogteLaagste bruikbare bedrijfshoogteVergrendel de secties en houd u aan de instructies
Contact met de ondergrondAlle voeten stabiel en volledig uitgeklaptVerplaats het statief of bereid het oppervlak voor
Blootstelling aan windVerwachting, windstoten en kopoppervlakVolg de gedocumenteerde limiet of verwijder het statief
Blootstelling aan impactWerknemers, deuren en voertuigenVerplaats, zet af of markeer het grondvlak
Trekkracht op de kabelRouting, speling en richting van de connectorBescherm de route en vermijd belasting door blijven haken

Request unit mass, deployed footprint, maximum height and any applicable stability or tip-over instructions. Do not describe the stand as windproof without model-specific evidence. Use only anchors, ballast or guying methods approved for the product and site; improvised weights can slide or introduce new trip hazards.

Plan de elektrische aansluiting en kabelroute

Confirm voltage, frequency, plug, cord type, grounding or insulation class, strain relief and destination-market documentation for the exact package. Temporary work sites may require ground-fault protection, approved distribution equipment and flexible cords suitable for the environment.

Route the cable away from walkways and vehicle paths. Where a crossing cannot be avoided, use an approved protector and preserve visibility. Leave enough slack for head and mast adjustment without pulling the inlet, but avoid loose loops that create trip or heat-management problems.

Inspecteer vóór elk gebruik de stekker, het snoer, de invoer en de trekontlasting. Neem beschadigde apparatuur uit gebruik. De LED product compliance document checklist kan aan de bestemmingsmarkt worden aangepast, terwijl de LED driver and control compatibility guide helpt voedings- en controles van bedrijfstoestanden te koppelen aan de exacte configuratie.

Interpreteer IP- en claims voor buitengebruik beperkt

An enclosure rating must be tied to the exact tested configuration and covered parts. A rated lamp head does not automatically protect an open plug, extension connection, switch or damaged cable. Confirm what the model-level report covers and how connectors must be positioned or protected.

IP65 does not establish immersion, unlimited storm exposure, salt resistance, impact resistance, every operating temperature or hazardous-location suitability. The IP65 fixture environmental selection guide maakt onderscheid tussen het binnendringen van water en stof en risico's door condensatie, corrosie, temperatuur en mechanische belasting.

If flammable gas, vapor or combustible dust may be present, use equipment specifically approved for the classified location and follow the site’s hazardous-area process. A normal outdoor or IP statement is not a substitute.

Controleer flikkering, kleur en visuele kwaliteit

Select correlated color temperature and color rendering according to the task, inspection needs and adjacent lighting. For rotating machinery, cameras or visually sensitive work, request temporal-light-modulation data for the exact driver and supply.

Een telefooncamera kan screenen op duidelijke strepen, maar kan geen productprestaties vaststellen. Gebruik de testaanpak in de LED flicker, power factor and THD checklist en neem elk aggregaat of tijdelijk verdeelsysteem op dat op locatie wordt gebruikt.

Also observe contrast outside the beam. A very bright task surrounded by darkness can impair adaptation and movement. Reposition the heads or provide background illumination instead of increasing one local hot spot indefinitely.

Test draagbaarheid als een herhaalbare workflow

Portability includes total kit mass, folded dimensions, handle positions, setup time, cable storage and transport protection. Test the actual case or vehicle arrangement. Identify pinch points during folding and secure the mast, crossbar and heads so they do not strike other equipment.

For rental fleets or shared tools, assign an asset identity and record cord, stand and head inspections. Keep replacement feet, locks and fasteners controlled by the approved configuration. The LED lighting supplier factory audit checklist en New Lights overzicht van fabriek en productie bieden een bredere context voor productie en wijzigingsbeheer.

Voer een representatieve acceptatietest op locatie uit

Set up the production-intent unit at the planned location, height and aim. Measure the work and access grid, then observe glare and shadows with people and equipment present. Verify stand locks, footprint, cable route, switching, power recovery and environmental protection.

Five-step tripod work-light site acceptance workflow covering placement, aiming, measurement, inspection and records
Plaats, richt uit, meet, inspecteer en leg de exacte configuratie van de tijdelijke verlichting vast.
AcceptatieverslagMinimaal bewijsVoorwaarde voor slagen
ProductidentiteitKop, driver, statief, snoer en stekkerKomt overeen met de goedgekeurde configuratie
VerlichtingsresultaatGridmetingen en observatienotitiesVoldoet aan taak- en toegangscriteria
Mechanische opstellingHoogte, vergrendelingen, grondvlak en ondergrondStabiel onder toegestane omstandigheden
Elektrische opstellingVoeding, bescherming en kabelrouteVoldoet aan de vereisten van locatie en markt
AfwijkingenSchade, verblinding, schaduwen of blootstellingAfgesloten vóór vrijgave

Gebruik de LED lighting sample evaluation checklist om het bewijs te behouden. Herhaal de betrokken controles na verplaatsing, wijzigingen aan onderdelen of schade die de veiligheid of lichtverdeling kunnen wijzigen.

Stuur voor een OEM- of projectbeoordeling het werkgebied, de beoogde verlichtingssterkte, montagehoogte, bodemgesteldheid, blootstelling aan wind, voedingsbron, kabelroute en doelmarkt wanneer u neem contact op met New Lights.

Veelgestelde vragen

Is de statieflamp met het hoogste vermogen altijd de beste keuze?

Nee. Kies op basis van geleverde verlichtingssterkte, gelijkmatigheid, verblinding, schaduwen, elektrische belasting en beperkingen bij de opstelling. Een hoger wattage kan een hotspot creëren zonder het volledige werkgebied te verbeteren.

How high should a tripod LED work light be?

Gebruik de laagste hoogte die obstakels vrijhoudt en de vereiste dekking biedt. Een grotere hoogte kan de mechanische belasting op de basis verhogen.

Can an IP65 tripod light be left in heavy rain?

Do not decide from IP65 alone. Verify the tested parts, plug and connector protection, product instructions and actual weather exposure.

Kan deze op een gevaarlijke locatie worden gebruikt?

Alleen wanneer het complete product specifiek is goedgekeurd voor het geclassificeerde gevaar en de procedures van de locatie dit toelaten. Een normale IP-classificatie is onvoldoende.

Wat moet vóór elk gebruik worden gecontroleerd?

Controleer beide koppen, lenzen, verstelvergrendelingen, dwarsbalk, mastvergrendelingen, poten, voeten, bevestigingsmiddelen, kabel, stekker, trekontlasting en tekenen van vocht of impact.

Hoe kunnen harde schaduwen worden verminderd?

Richt de twee koppen op elkaar aanvullende zones of gebruik meer dan één lichtpositie. Bevestig het resultaat met de taak en obstakels aanwezig.

Redactionele bronnen

  • New Lights, “Dual-Head LED Flood Light Tripod”: https://www.new-lights.com/products/led-work-lights/led-flood-light-tripod/
  • New Lights, catalogus “Flood & Work Light”: https://www.new-lights.com/new-lights/2024/12/06/floodworklight.pdf
  • U.S. Occupational Safety and Health Administration, “1926.56 Verlichting”: https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.56
  • U.S. Occupational Safety and Health Administration, “Electrical Hazards in Construction Student Workbook”: https://www.osha.gov/sites/default/files/2022-01/Electrical%20Hazards%20in%20Construction%20Student%20Workbook.pdf
PROJECT INQUIRY
Bespreek uw verlichtingsbriefing met New Lights

Share the target application, market, estimated quantity, installation constraints, control requirements, packaging needs, and the files you already have. We can then identify a suitable product direction and the questions that still need confirmation.

Need a full RFQ? Open the contact form →

ON THIS PAGE

In This Article

AUTHOR

Picture of Raymond Koo

Global Sales Director at New Lights

Scroll to Top

Send Us a Message

Leave your contact details and message. Our team will reply by email or through your preferred contact method.

Tell Us About Your Lighting Project

Share your product, application and purchasing requirements. Our lighting team will reply with suitable options and project support.