New Lights

3-CCT Selectable LED Bulbs

These LED bulbs use an on-body selector for 3000 K, 4000 K or 6500 K white light. The indoor series covers MR16, GU10, A60, T37, T45, C37 and G45 forms from 5 to 12 W.
  • On-Body Three-Position Selector: A physical switch sets one fixed white-light option without app or wireless control.
  • HJ01 and HJ02 Housings: HJ01 and HJ02 body families provide visibly distinct neck and housing treatments, including the orange-ring HJ02 forms.
  • Reflector and Diffused Forms: MR16 and GU10 bodies provide directional distributions, while the bulb, tubular, candle and globe forms use broader diffusion.
  • No-Flicker Driver Design: The integrated driver is specified for no-flicker normal operation.
Body FormatsMR16 / GU10 / A60 / T37 / T45 / C37 / G45
Power Range5-12 W
CCT Control3000 / 4000 / 6500 K slide selection
Efficacy & CRI80 or 90 lm/W; Ra80 / Ra90
Beam Options36 / 110 / 120 / 200 degrees by body
Input & Use220-240 V; indoor

Technical Specifications

Model Specifications

ModelSize D x H (mm)PowerEfficacyCCTBeamInput / CRIDimming / Life
XGYSMD-MR16-HJ01-3CCT50 x 556 W80 lm/W3000 / 4000 / 6500 K36 / 110 degrees220-240 V; Ra80/90Optional; 15-25k h
XGYSMD-GU10-HJ01-3CCT50 x 565 W80 lm/W3000 / 4000 / 6500 K36 / 110 degrees220-240 V; Ra80/90Optional; 15-25k h
XGYSMD-GU10-HJ01-3CCT50 x 566 W80 lm/W3000 / 4000 / 6500 K36 / 110 degrees220-240 V; Ra80/90Optional; 15-25k h
XGYSMD-GU10-HJ01-3CCT50 x 567 W80 lm/W3000 / 4000 / 6500 K36 / 110 degrees220-240 V; Ra80/90Optional; 15-25k h
XGYSMD-A60-HJ01-3CCT60 x 1089 W90 lm/W3000 / 4000 / 6500 K200 degrees220-240 V; Ra80/90Optional; 15-25k h
XGYSMD-A60-HJ01-3CCT60 x 11812 W90 lm/W3000 / 4000 / 6500 K200 degrees220-240 V; Ra80/90Optional; 15-25k h
XGYSMD-T37-HJ01-3CCT37 x 1158 W90 lm/W3000 / 4000 / 6500 K200 degrees220-240 V; Ra80/90Optional; 15-25k h
XGYSMD-T45-HJ01-3CCT45 x 13912 W90 lm/W3000 / 4000 / 6500 K200 degrees220-240 V; Ra80/90Optional; 15-25k h
XGYSMD-A60-HJ02-3CCT60 x 11310 W90 lm/W3000 / 4000 / 6500 K120 degrees220-240 V; Ra80/90Optional; 15-25k h
XGYSMD-C37-HJ02-3CCT35 x 1066 W80 lm/W3000 / 4000 / 6500 K120 degrees220-240 V; Ra80/90Optional; 15-25k h
XGYSMD-G45-HJ02-3CCT45 x 886 W80 lm/W3000 / 4000 / 6500 K120 degrees220-240 V; Ra80/90Optional; 15-25k h

The A60 HJ01 reference has separate 9 W / 108 mm and 12 W / 118 mm rows. Series-level bases are not mapped to every row.

Product Description

Product Details

Product Construction

SMD LED assemblies are enclosed within replaceable reflector, general-service, tubular, candle and globe lamp forms. Series-level base formats include GU5.3, GU10, E26 and E27, with the required base confirmed for the selected model.

Selection & Installation Notes

Choose by lamp form, wattage, overall D x H size and beam angle. XGYSMD-A60-HJ01-3CCT has separate 9 W / 108 mm and 12 W / 118 mm configurations under the same model reference, so both wattage and height must be stated. Disconnect power before installing or removing the lamp. Dimming is optional and must be ordered with a compatible dimmer version.

Recommended Application

Applications

  • Living Rooms: Select warm, neutral or daylight white for general indoor lighting with compatible lamp holders.
  • Bedroom Lighting: Use A60, candle or globe forms in open bedside, ceiling or decorative indoor fixtures.
  • Retail Displays: Use MR16 or GU10 forms for directional merchandise lighting with the required beam choice.
  • Hospitality Interiors: Match selectable white light to guest rooms, corridors, lounges and reception areas.
Keep
in touch

Tell Us Your Market and Product Needs

Share your market, product interest, application, or estimated quantity. Our team can help you move faster from product selection to quotation and sample discussion.

By submitting this form, you ask New Lights Lighting Technology Co., Ltd. to use the information you provide to respond to your inquiry and manage related business communications. See our Privacy Policy. Optional marketing emails require the separate choice below.

Frequently Asked Questions?

Find clear answers to common questions about product specifications, model selection, applications, and quotation requirements. For project-specific needs, send us your target market, required quantity, and key specifications.

How is the color temperature changed?

Use the selector on the lamp body to choose 3000 K, 4000 K or 6500 K. Isolate power before handling the bulb or changing the selector.

Is this a tunable-white or smart bulb?

No. It provides three fixed white-light presets through a physical selector rather than continuous tuning, app control or wireless control.

Why do the listed beam angles differ by model?

MR16 and GU10 bodies use 36- or 110-degree distributions, HJ02 diffused bodies use 120 degrees, and the A60/T37/T45 HJ01 forms use 200 degrees.

Is every model dimmable?

No. Dimming is optional, so specify the dimmable version and confirm dimmer compatibility for the exact order.

Which lamp bases are available?

Series-level options include GU5.3, GU10, E26 and E27. Confirm the required base for the selected model before ordering.

Can these bulbs be used outdoors?

No confirmed IP rating applies to this indoor series. Use it indoors unless a separately rated version is confirmed for the installation.

Featured Products

Scroll to Top

Send Us a Message

Leave your contact details and message. Our team will reply by email or through your preferred contact method.

By submitting this form, you ask New Lights Lighting Technology Co., Ltd. to use the information you provide to respond to your inquiry and manage related business communications. See our Privacy Policy. Optional marketing emails require the separate choice below.

Tell Us About Your Lighting Project

Share your product, application and purchasing requirements. Our lighting team will reply with suitable options and project support.

By submitting this form, you ask New Lights Lighting Technology Co., Ltd. to use the information you provide to respond to your inquiry and manage related business communications. See our Privacy Policy. Optional marketing emails require the separate choice below.